Randell 20048SCF-32 Návod k obsluze Strana 1

Procházejte online nebo si stáhněte Návod k obsluze pro ne Randell 20048SCF-32. Randell 20048SCF-32 Operator`s manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 51
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
12/12/2007
PP MNL0705-REV B
OPERATOR’S MANUAL
This manual provides information on
installation, operating, maintenance,
trouble shooting & replacement
parts for
Refrigerated Solutions with
FlexiCold Technology
FX
FXFX
FX-
--
-1
11
1
2N1 TWO COOLING SYSTEMS IN ONE
Refrigerator (4F)
• Freezer (-5°F)
• Or anywhere in between (-5° to 40°F)
FX
FXFX
FX1
11
1-
--
-4
44
4N
NN
N1
11
1
4N1 FOUR COOLING SYSTEMS IN ONE
Refrigerator (40°F)
• Freezer (-5°F)
• Or anywhere in between (-5° to 40°F)
• Rapid Chiller for on-demand blast
chilling
• Safety Thaw for on-demand thawing of
frozen food safely
NOTIFY CARRIER OF DAMAGE AT ONCE.
It is the responsibility of the consignee to inspect
the container upon receipt of same and to
determine the possibility of any damage, including
concealed damage. Randell suggests that if you
are suspicious of damage to make a notation on
the delivery receipt. It will be the responsibility of
the consignee to file a claim with the carrier. We
recommend that you do so at once.
Manufacture Service/Questions 888-994-7636.
Information contained in this document is known to be
current and accurate at the time of printing/creation.
Unified Brands recommends referencing our product line
websites, unifiedbrands.net, for the most updated
product information and specifications.
1055 Mendell Davis Drive
Jackson, MS 39272
888-994-7636 Fax 888-864-7636
randellfx.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 50 51

Shrnutí obsahu

Strany 1 - PP MNL0705-REV B

12/12/2007 PP MNL0705-REV B OPERATOR’S MANUAL This manual provides information on installation, operating, maintenance, trouble shooting & replace

Strany 2 - 888-994-7636

10101010 888-994-7636 Unit Specifications Model FX-2WS Double Flexi-Cold Drawer Model Description L E N

Strany 3 - Table of Contents

randellfx.com 11111111 Model Description L E N G T H D E P T H H E I G H T SECT IONS CUBIC FEET OF STORAGE COMPRESSOR SIZE ACTUAL AMP DRA

Strany 4 - Hotline

12121212 888-994-7636 Unit Installation SELECTING A LOCATION FOR YOUR NEW UNIT The following conditions sho

Strany 5 - Warranty Policies

randellfx.com 13131313 Unit Installation con’t ELECTRICAL SUPPLY: Any wiring should be done by a qualified electrician in accordance wi

Strany 6 - Warranty Policies con’t

14141414 888-994-7636 Gasket Sealing Adjustment

Strany 7

randellfx.com 15151515 FX-1 (2N1) Unit Operation PRODUCT PLACEMENT AND MAXIMUM LOAD LEVELS 1. This unit’s insulated drawer insert

Strany 8

16161616 888-994-7636 FX-1 (2N1) Control Operation AMBIENT CONDITIONS 1. This unit is designed for operatio

Strany 9

randellfx.com 17171717 FX-1 (2N1) Control Settings Dixell control XR60C-4N1F0 w/Red LED Randell Control Settings FX-Series XR60C

Strany 10 - Unit Specifications

18181818 888-994-7636 FX-1 (2N1) Control Settings Dixell control XR60CX-4N1F0 w/Blue LED Randell Control

Strany 11 - Model Description

randellfx.com 19191919 FX-1 (2N1) Control LED Functions USE OF LEDS Each LED function is described in the following table.

Strany 13 - Unit Installation con’t

20202020 888-994-7636 FX-1 (2N1) Control Settings DIXELL CONTROL SETTING INSTRUCTIONS HOW TO CHANGE A PARAM

Strany 14 - Gasket Sealing Adjustment

randellfx.com 21212121 FX1- 4N1 Control Operation ELECTRONIC CONTROL FEATURES AND OPERATIONS Randell has attempted to preset the temper

Strany 15 - FX-1 (2N1) Unit Operation

22222222 888-994-7636 FX1- 4N1 Control Operation con’t Running cycle H Hold Mode o

Strany 16 - FX-1 (2N1) Control Operation

randellfx.com 23232323 FX1- 4N1 Control Operation con’t CONTROL KEY DESCRIPTIONS 1. UP/TEMP/MANUAL DEFROST – used to browse menu, rais

Strany 17 - Dixell control

24242424 888-994-7636 FX1- 4N1 Control Operation con’t HOW TO SET THE CYCLE OF OPERATION TO CHANGE THE CYCL

Strany 18 - FX-1 (2N1) Control Settings

randellfx.com 25252525 FX1- 4N1 Control Operation con’t TO CHANGE THE TEMPERATURE SETTING FOR CYCLE HHHH (HOLD): Follow the instructio

Strany 19 - USE OF LEDS

26262626 888-994-7636 FX1- 4N1 Control Settings RANDELL CONTROL SETTINGS FX1-4N1 DIXELL PART NUMBER X

Strany 20

randellfx.com 27272727 FX1- 4N1 Control Settings con’t RANDELL CONTROL SETTINGS FX1-4N1 DIXELL PART NUMBER XB570L-4R0F1 RAN

Strany 21 - FX1- 4N1 Control Operation

28282828 888-994-7636 FX1- 4N1 Control Settings con’t RANDELL CONTROL CYCLE SETTINGS FX1-4N1 RANDEL

Strany 22

randellfx.com 29292929 FX1- 4N1 Control LED Functions MEANING OF THE LED DISPLAYS A series of light points on the front panels is used t

Strany 23

randellfx.com 3333 Table of Contents page 2………………….….Table of Contents & Congratulations page 3……..Serial Number Location & Par

Strany 24

30303030 888-994-7636 FX1-4N1 Unit Operation UNIT OPERATION, PRODUCT PLACEMENT AND MAXIMUM LOAD LEVELS FOR

Strany 25 - (HOLD):

randellfx.com 31313131 3 FX1-4N1 Unit Operation con’t 4. Place the cooked product in 12”x20”x2-1/2” deep pans and cover for quicker c

Strany 26 - FX1- 4N1 Control Settings

32323232 888-994-7636 3 3 3 (continued on page 25) FX1-4N1 Unit Operation con’t In the program mode press

Strany 27

randellfx.com 33333333 3 FX1-4N1 Unit Operation con’t 8. The plug on the Product Probe has a positive (+) and negative (- in red) pr

Strany 28

34343434 888-994-7636 FX1-4N1 Unit Operation con’t RAPID THAW OPERATION: 1. To efficiently thaw product q

Strany 29 - MEANING OF THE LED DISPLAYS

randellfx.com 35353535 4 FX1-4N1 Unit Operation con’t 1. HOW TO START THE RAPID THAW CYCLE Press and hold the START/STOP key unti

Strany 30 - FX1-4N1 Unit Operation

36363636 888-994-7636 Preventive Maintenance Randell strongly suggests a preventive maintenance program whi

Strany 31 - FX1-4N1 Unit Operation con’t

randellfx.com 37373737 Preventive Maintenance (cont.) Proper maintenance of equipment is the ultimate necessity in preventing

Strany 32

38383838 888-994-7636 FX-1 (2N1) Electrical Diagram N - WHITEFAN - BLUEL1 - BLACKDEFROST - YELLOWCOMPR - BROW

Strany 33

randellfx.com 39393939 FX1- 4N1 Electrical Diagram COPELAND COMPRESSOR16A250Vac8A250Vac8A250Vac16A250VacSUPPLY115VCOMPFANAUX.DEF.XB570LPR

Strany 34

4444 888-994-7636 In addition, all Randell food service equipment is backed by some of the best war

Strany 35

40404040 888-994-7636 Trouble Shooting Guide SYMPTOM POSSIBLE CAUSE PROCEDURE 1. No power to unit 1. Pl

Strany 36 - Preventive Maintenance

randellfx.com 41414141 Replacement Parts List FX-1 (2N1) SERIES REFRIGERATION SYSTEMS

Strany 37

42424242 888-994-7636 Replacement Parts List FX-1 (2N1) SERIES REFRIGERATION SYSTEMS ITEM DESCRIPTION PART

Strany 38 - COMPR - BROWN

randellfx.com 43434343 Replacement Parts List FX-1 (2N1) SERIES REFRIGERATION SYSTEMS ITEM DESCRIPTION PART # 32 EVAPORATOR COIL

Strany 39 - FX1- 4N1 Electrical Diagram

44444444 888-994-7636 Replacement Parts List FX1-4N1 SERIES REFRIGERATION SYSTEMS

Strany 40 - Trouble Shooting Guide

randellfx.com 45454545 Replacement Parts List FX1-4N1 SERIES REFRIGERATION SYSTEMS ITEM DESCRIPTION PART # 1 DRAWER FRONT PANEL RP

Strany 41 - REFRIGERATION SYSTEMS

46464646 888-994-7636 Replacement Parts List FX1-4N1 SERIES REFRIGERATION SYSTEMS

Strany 42

randellfx.com 47474747 Replacement Parts List FX1-4N1 SERIES REFRIGERATION SYSTEMS ITEM DESCRIPTION PART # 26 LOUVER FRONT PANEL R

Strany 43

48484848 888-994-7636 Replacement Parts List FX1-4N1 SERIES REFRIGERATION SYSTEMS ITEM DESCRIPTION PART #

Strany 44 - FX1-4N1 SERIES

randellfx.com 49494949 Replacement Parts List FX SERIES OPTIONAL ACCESSORY PARTS

Strany 45

randellfx.com 5555 Warranty Policies Congratulations on your purchase of a Randell Manufactured piece of equipment. Randell believes

Strany 46

50505050 888-994-7636 Replacement Parts List FX SERIES OPTIONAL ACCESSORY PARTS CON’T ITEM DESCRIPTION PA

Strany 47

randellfx.com 51515151 NOTES

Strany 48

6666 888-994-7636 Warranty Policies con’t Temperature adjustments are not covered under warranty, due to th

Strany 49 - OPTIONAL ACCESSORY PARTS

randellfx.com 7777 Warranty Policies con’t ITEMS NOT COVERED UNDER WARRANTY 1. Maintenance type of repairs such as condenser cleaning,

Strany 50 - ITEM DESCRIPTION PART #

8888 888-994-7636 Warranty Policies con’t STORAGE CHARGES Randell makes every effort to consistently

Strany 51

randellfx.com 9999 Warranty Policies con’t RETURNED GOODS Authorization for return must first be obtained from Randell before

Komentáře k této Příručce

Žádné komentáře